New Holland UCM 1206 – UCM: Parameter Validation: Configuration Response Timed Out

Issue description

Communication failure on the CAN bus. The control module is expecting a configuration response or parameter validation from another module (often the Instrument Cluster), but the response is not received within the programmed time limit.

Applies to these machines

  • L213
  • L215
  • L218
  • L220
  • L223
  • L225
  • L230
  • C227
  • C232
  • C238
  • SR175
  • B90B
  • B100B

Check the cause

  1. Verify the physical CAN network connections between the UCM and the Instrument Cluster (IC)

  2. Inspect the wiring harness for an open circuit, short circuit to ground, or short circuit to power that could interrupt CAN communication

  3. Ensure the UCM is receiving proper voltage by checking the power supply, UCM power relay, and fuses

Repair steps

  1. Disconnect Power

    Turn off the machine and use the battery quick-disconnect switch (if equipped) to disconnect the negative battery cable before servicing the electrical system.

  2. Inspect the Fuse Box

    Locate the double fuse box and check the WIC UCM Power circuit (typically a 35A relay/fuse).

  3. Test the UCM Power Relay

    Test or swap the 12V 35A micro relay responsible for powering the UCM. If the relay is burnt out or sticking, the UCM will not communicate on the CAN bus.

  4. Harness Repair

    If the relay is functional, trace the CAN wiring from the UCM to the Instrument Cluster. Repair any chafed wires, clean corroded connector pins, and ensure all plugs are seated firmly.

  5. Module Replacement

    If the wiring, fuses, and relays are all intact, the UCM itself may have suffered an internal core monitoring fault or EEPROM failure and will need to be replaced and reprogrammed.

Parts you might need

(9)
  • UCM Power Relay (12V, 35A Micro Relay)

    87655334

    Superseded by 87696396. Replaces 416570A1, 84561098, and 87582879.

  • UCM Power Relay (Updated)

    87696396

    Updated part number superseding 87655334.

  • UCM Power Relay (Older)

    416570A1

    Older part number replaced by 87655334.

  • UCM Power Relay (Older)

    84561098

    Older part number replaced by 87655334.

  • UCM Power Relay (Older)

    87582879

    Older part number replaced by 87655334.

  • Electronic Control Unit / UCM

    47395504
  • Electronic Control Unit / UCM

    47395504R
  • Electronic Control Unit / UCM

    84267444
  • Electronic Control Unit / UCM

    84348127

Get help to fix this fault by requesting a quote