UCM 5513

New Holland UCM 5513 – UCM: Aux Control Function: Implausible State Sensor versus Auxiliary Command

Issue description

This fault code indicates a mismatch between the electrical command sent by the UCM to the auxiliary hydraulic system and the actual physical position of the auxiliary valve spool. The UCM monitors the spool's movement via a spool position sensor. When the operator commands auxiliary hydraulic flow, the UCM expects the sensor to report a corresponding shift in the spool. If the sensor reports an implausible state, code 5513 is triggered.

Applies to these machines

  • L213
  • L218
  • L220
  • L223
  • L230
  • C227
  • C238
  • SR175
  • SV185
  • TR270
  • SV300

Check the cause

  1. Inspect the wiring harness leading to the auxiliary valve spool position sensor on the main EH control valve for chafed wires, loose pins, or corrosion inside the connector.

  2. Verify that the sensor is receiving the correct reference voltage (typically 5V) and has a solid ground from the UCM.

  3. Determine if the auxiliary spool is physically stuck. A stuck spool or a stuck Pressure Relief Valve (PRV) will prevent the spool from shifting when the solenoids are energized.

  4. Monitor the sensor's signal voltage while commanding the auxiliary hydraulics. If the voltage does not change smoothly or is completely out of range, the sensor has likely failed.

Repair steps

  1. Relieve Hydraulic Pressure

    Lower the loader arms, turn off the engine, and cycle the hydraulic controls to relieve all residual pressure in the system.

  2. Access the Control Valve

    Locate the main EH loader control valve block, typically situated under the cab (the cab will need to be tilted and safely locked into place).

  3. Inspect/Clean the Valve Spool

    If diagnostics point to a stuck spool, carefully remove the spool position sensor end cap. Inspect the spool and the bore for metal debris, scoring, or contamination. Clean the spool and bore. If the spool is heavily scored, the valve section may need to be replaced.

  4. Replace the Sensor

    If the spool moves freely but the sensor output is erratic or dead, remove the faulty spool position sensor from the auxiliary section of the control valve.

  5. Install New Components

    Install the new spool position sensor. It is highly recommended to replace the associated O-rings on the EH spool cap and passages during this process to prevent leaks.

  6. Calibrate the Hydraulics

    After replacing the sensor or freeing a stuck spool, use the machine's display or a diagnostic service tool to perform an Electro-Hydraulic (EH) calibration. This allows the UCM to learn the new neutral, minimum, and maximum voltage values for the auxiliary spool sensor.

  7. Test Operation

    Start the machine and test the auxiliary hydraulic functions to ensure smooth operation and verify that code 5513 does not return.

Parts you might need

(4)
  • Spool Position Sensor (EH Loader Control Valve)

    84386295

    Manufactured for Case/New Holland; fits L200/C200 series EH control valves

  • Cap, Spool Position Sensor End

    84386296
  • O-Ring (EH Spool Cap)

    84386293
  • O-Ring (EH Spool Passage)

    84386294

Get help to fix this fault by requesting a quote