New Holland UCM 5603 – UCM: Aux Control Function: Solenoids Return Open Circuit
Issue description
This fault code indicates that the control module has detected a break in the electrical continuity (an open circuit) on the return (ground) side of the auxiliary hydraulic control solenoids. Because the circuit is open, electrical current cannot flow through the solenoid coils, meaning the machine will be unable to actuate the auxiliary hydraulic functions (used for running attachments).
Applies to these machines
17 machines- L213
- L215
- L216
- L218
- L220
- L221
- L223
- L225
- L228
- L230
- L234
- C227
- C232
- C234
- C237
- C238
- C245
Check the cause
Inspect the wiring harness leading to the loader control valve block for severed wires, chafing against the chassis, or unplugged connectors at the auxiliary solenoids.
Disconnect the auxiliary solenoid connectors and measure the resistance across the solenoid coil pins with a multimeter (a healthy coil reads 10 to 12 ohms; 'OL' indicates a broken/open coil).
If the coil tests good, check the continuity of the return wire from the solenoid connector back to the UCM harness connector.
Check the UCM connectors and the solenoid connectors for water intrusion, corrosion, or pins that have been pushed back out of the plastic housing.
Repair steps
Prepare the Machine
Lower the boom completely (or engage the boom locks if it must be raised for access). Turn off the ignition and engage the battery disconnect switch (or disconnect the negative battery cable).
Access the Valve Block
Tilt the cab forward (following the operator's manual safety procedures) to access the main loader control valve block where the auxiliary solenoids are mounted.
Repair the Wiring (If Applicable)
If the diagnostic tests revealed a broken return wire, locate the break. Cut out the damaged section and splice in a new wire using marine-grade, heat-shrink butt connectors to prevent future moisture intrusion.
Replace the Solenoid Coil (If Applicable)
Disconnect the electrical pigtail from the faulty auxiliary solenoid. Remove the retaining nut at the end of the solenoid cartridge stem. Slide the faulty coil off the valve stem. (Note: You usually do not need to open the hydraulic system or remove the valve cartridge just to replace the coil). Slide the new OEM coil onto the stem, reinstall the retaining nut, and plug in the connector.
Reassembly and Testing
Lower and secure the cab. Reconnect the battery. Turn the ignition on, clear the UCM fault codes using the diagnostic menu or a scan tool, and test the auxiliary hydraulics with an attachment to verify the repair.
Parts you might need
(5)Auxiliary Solenoid Valve Coil
86837739Common 12V coil used on New Holland 200-series loader valves
Auxiliary Solenoid Valve Coil
86995304Common 12V coil used on New Holland 200-series loader valves
Hydraulic Valve Solenoid
84386288Cartridge & Coil Assembly
Complete Loader Control Valve
47408221Reference for the entire block assembly (E-H Controls)
Complete Loader Control Valve
47408223Reference for the entire block assembly (E-H Controls)