New Holland fault codes & repair guides
All 7,052 codes· 50 per page · page 66 of 142
| Code | Controller | Issue summary | Repair manual |
|---|---|---|---|
| 5030 | New Holland Rear Power Take Off | Shaft Size Speed Sensor Open or Short to B+ PTO Small Shaft Switch | Full repair manual for code 5030, New Holland Rear Power Take Off |
| 5030 | Rear PTO | Shaft Size Speed Sensor Circuit Issue | Full repair manual for code 5030, Rear PTO |
| 5031 | — | Short Circuit to Ground of the Sensor of the Rotational Speed of the Shaft | Full repair manual for code 5031 |
| 5031 | New Holland Rear Power Take Off | Shaft Size Speed Sensor Short to Ground | Full repair manual for code 5031, New Holland Rear Power Take Off |
| 5031 | Rear PTO | Shaft Size Speed Sensor Short to GND | Full repair manual for code 5031, Rear PTO |
| 5032 | — | Low Power Voltage 12VF3 | Full repair manual for code 5032 |
| 5032 | New Holland Rear Power Take Off | Low Voltage Supply in 12VF3 | Full repair manual for code 5032, New Holland Rear Power Take Off |
| 5032 | Rear PTO | Low Voltage Supply to Rear PTO | Full repair manual for code 5032, Rear PTO |
| 5033 | — | Break in the circuit of the normally closed switch located in the cabin | Full repair manual for code 5033 |
| 5034 | — | Circuit Break / Short to 'Ground' of the Reverse Gear Switch Located on the Fender | Full repair manual for code 5034 |
| 5035 | — | Short Circuit in Reverse Gear Switch Input | Full repair manual for code 5035 |
| 5037 | — | Cab Rear PTO Switch Jammed On (Normally Off) | Full repair manual for code 5037 |
| 5037 | — | Cabin-mounted Normally Open Reverse Switch Sticking in Closed Position | Full repair manual for code 5037 |
| 5042 | — | Control Switch PTO - Stuck in Closed Position | Full repair manual for code 5042 |
| 5043 | — | Reverse Gear Switch on the Wing Stuck in On Position | Full repair manual for code 5043 |
| 5043 | — | Rear PTO Fender Switch Stuck On | Full repair manual for code 5043 |
| 5044 | — | PTO Speed Sensor Short Circuit to Ground | Full repair manual for code 5044 |
| 5045 | — | Ground Speed PTO Switch Open or Short to GND | Full repair manual for code 5045 |
| 5046 | — | Ground Speed PTO Switch Short to 12V | Full repair manual for code 5046 |
| 5047 | — | Ground Speed PTO Configuration Error | Full repair manual for code 5047 |
| 5051 | UCM | Hydraulics Enable: Solenoid Supply Open Circuit | Full repair manual for code 5051, UCM |
| 5052 | — | Loader Pilot Interlock Valve (On/Off) - Solenoid Supply Short to Ground | Full repair manual for code 5052 |
| 5053 | UCM | Hydraulics Enable: Solenoid Supply Short to Power | Full repair manual for code 5053, UCM |
| 5062 | — | Port Lock Valve (On/Off) - Solenoid Supply Short to Ground | Full repair manual for code 5062 |
| 5062 | UCM | Loader Port Lock: Solenoid Supply Short to Ground | Full repair manual for code 5062, UCM |
| 5063 | — | Port Lock Valve (On/Off) - Solenoid Supply Short to Power | Full repair manual for code 5063 |
| 5063 | UCM | Loader Port Lock: Solenoid Supply Short to Power | Full repair manual for code 5063, UCM |
| 5099 | — | Rear PTO Management Option Not Activated | Full repair manual for code 5099 |
| 5121 | UCM | Boom Raise/Lower Circuit Issue | Full repair manual for code 5121, UCM |
| 5121 | UCM | Ground Drive Circuit Fault | Full repair manual for code 5121, UCM |
| 5122 | UCM | Boom Raise/Lower Circuit Fault | Full repair manual for code 5122, UCM |
| 5122 | UCM | Ground Drive Circuit Fault | Full repair manual for code 5122, UCM |
| 5124 | UCM | Boom Raise/Lower: In-Range Fault | Full repair manual for code 5124, UCM |
| 5131 | — | Right Joystick R-L Axis (ISO/H Pattern) - Pin A Short to Ground/ Open Circuit | Full repair manual for code 5131 |
| 5131 | UCM | Bucket Rollback / Dump: Pin A Short to Ground / Open Circuit | Full repair manual for code 5131, UCM |
| 5132 | — | Right Joystick R-L Axis (ISO/H Pattern) - Pin A Short to Power | Full repair manual for code 5132 |
| 5134 | — | Right Joystick R-L Axis (ISO/H Pattern) - Pin B Short to Ground/ Open Circuit | Full repair manual for code 5134 |
| 5134 | UCM | Bucket Rollback / Dump: Pin B Short to Ground / Open Circuit | Full repair manual for code 5134, UCM |
| 5135 | — | Right Joystick R-L Axis (ISO/H Pattern) - Pin B Short to Power | Full repair manual for code 5135 |
| 5135 | UCM | Bucket Rollback / Dump: Pin B Short to Power | Full repair manual for code 5135, UCM |
| 5137 | — | Right Joystick R-L Axis (ISO/H Pattern) - In Range Fault | Full repair manual for code 5137 |
| 5141 | — | Auxiliary Thumbwheel Axis - Pin A Fault | Full repair manual for code 5141 |
| 5141 | UCM | Auxiliary Control Function: Pin A Short to Ground or Open Circuit | Full repair manual for code 5141, UCM |
| 5142 | — | Auxiliary Thumbwheel Axis - Pin A Short to Power | Full repair manual for code 5142 |
| 5144 | — | Auxiliary Thumbwheel Axis - Pin A Fault | Full repair manual for code 5144 |
| 5145 | — | Auxiliary Thumbwheel Axis - Pin A Short to Power | Full repair manual for code 5145 |
| 5147 | — | Auxiliary Thumbwheel Axis - In Range Fault | Full repair manual for code 5147 |
| 5201 | — | Left Joystick L-R Axis - Pin A Fault | Full repair manual for code 5201 |
| 5201 | UCM | Boom Raise/Lower Circuit Issue | Full repair manual for code 5201, UCM |
| 5201 | UCM | Ground Drive Circuit Fault | Full repair manual for code 5201, UCM |