For runs up to about 4 m on a 12 V system, 1.5 mm² copper carries up to roughly 10 A, 2.5 mm² up to 20 A and 4 mm² up to 30 A. Four 48 W LED work lights draw 16 A at 12 V and therefore need 2.5 mm². On 24 V the current halves, so the same cable carries twice the wattage.
On a standard automotive relay, 30 is the fused feed from the battery, 87 is the output to the lamps, and 85 and 86 are the two ends of the coil, one to the switch and one to earth. A fifth terminal, 87a, is live when the relay is at rest and is left unused in a lighting circuit.
Rate the fuse about 25 to 50 per cent above the working current and never above what the cable can carry: a 16 A load takes a 20 or 25 A fuse on 2.5 mm² cable. Fit it as close to the supply as possible, ideally within 30 cm of the battery or power stud, so the whole cable run is protected.
The 7-pin plug carries the basic road lighting: left and right indicators, left and right tail lamps, stop lamps, rear fog lamp and earth. The 13-pin plug carries the same circuits and adds reversing lamps, a permanent live feed, an ignition-switched feed and separate earths for them. Adapters join one to the other, but the extra functions work only where both sides are 13-pin.
Aim for no more than about 3 per cent between the supply and the lamp: roughly 0.4 V on a 12 V system and 0.7 V on a 24 V system. Greater drop dims halogen lamps noticeably and can make LED lamps flicker or cut out. Longer runs need a larger cross-section, not a larger fuse.
A single small LED lamp drawing 2 to 3 A can be run directly through a switch rated for that current. Above about 5 A in total a relay is advisable, and it is the correct method whenever the trigger is taken from an existing lighting circuit, because the original wiring then carries only the relay coil current of around 0.15 A.
Use crimp connectors with adhesive-lined heat-shrink sleeves, or sealed plug connectors with individual wire seals. Avoid insulation-displacement tap connectors and bare twisted joints under tape, which corrode within a season. Route the cable so that it rises into each connector, forming a drip loop, and protect it with conduit and grommets wherever it passes through metal.