Dampening
elastische Dämpfungsringe/-platten beidseitig
Fastening Type
with female thread
Operating Medium
Compressed air to ISO 8573-1:2010 [6:4:4]
Position Detection
mit Winkelmesssystem integriert
Construction Set Up
Rotary vane
Protection Category
acc. to IEC 60529
Drive Shaft Material
Nickel-plated steel
Feather Key Material
Steel
Rotary Vane Material
PET reinforced
Independent Linearity
0,0025
Plug Housing Material
PA reinforced
Cylinder Tube Material
Aluminium wrought alloy
LABS (PWIS) Conformity
VDMA24364-B2-L
Principle Of Operation
double acting
Stopper Lever Material
eloxiert
Operating Pressure (MPa)
0,2 to 1
Ambient Temperature (°C)
60
Fixed Limit Stop Material
Steel
Recommended Wiper Current
1
Repeatability Positioning
± 0,3 deg
Max. Mass Inertia, Vertical
0,12
Smallest Positioning Stroke
15 ° bei Soft Stop
Max. Mass Inertia, Horizontal
0,12
Max. Operating Voltage DC (V)
42
Corrosion Resistance Class KBK
0 - No corrosion stressing
Integration Position Soft Stop
horizontal
Permitted Voltage Oscillations
< 1 %
Tolerance Connection Resistance
20
Nominal Operating Voltage DC (V)
10
Settings Range Swivel Angle (°)
0 to 270
Position The Integration Location
arbitrary
Housing Measurement System Material
eloxiert
Max. Grinder Current Short Term (mA)
10.000
Measurement System Coupling Material
TPE-U(PU)
Note On Operating And Control Medium
Oiled operation not possible
Repeatability Soft Stop End Position
< 0.2 deg
Min. Mass Moment Of Inertia, Vertical
0,006
Stroke Reduction At The End Positions
5 °
Impact Energy At The End Positions (Nm)
0,1
Min. Mass Moment Of Inertia, Horizontal
0,006
Oscillation Strength To DIN/IEC 68 Part 2-6
Tested to severity class 2
UKCA Marking (See Declaration Of Conformity)
nach UK RoHS Vorschriften
Repeatability Soft Stop Intermediate Position
± 2 deg
CE Certificate (See Declaration Of Conformity)
nach EU-RoHS-Richtlinie
Electrical Connection: Path Measurement System
4 pin
Continuous Impact Strength DIN&EC 68 Parts 2-82
Tested to severity class 2
Measurement Principle Travel Measurement System
Analogue
Operating Pressure Positioning / Soft Stop (bar)
4 to 8
Typical Positioning Time Long Stroke, Horizontal
0,30/0,55 s
Typical Positioning Time Short Stroke, Horizontal
0,25/0,25 s
Theoretical Torque At 0.6 MPa (6 bar, 87 psi) (Nm)
20
Max. Swivel Frequency At 0.6 MPa (6 bar, 87 psi) (Hz)
2