Festo - VABX-A-P-EL-E12-IOL-SHUH-XL-8189591 - Manifold Plate

SKU: festo-vabx-a-p-el-e12-iol-shuh-xl-8189591

Festo - VABX-A-P-EL-E12-IOL-SHUH-XL-8189591 - Manifold Plate

€154.65€132.18 (Excl. VAT)

In stock - ready to ship

Order now for shipping within 4 to 6 business days

Shipping fee: €9.99 incl. VAT

Pay Securely with

Price

€154.65

Brand
Size
2
Report
IO-Link
KC-mark
KC-EMV
Permission
RCM mark
Cable Output
straight
Nut Material
High-alloyed stainless steels
Foil Material
Polyester
Material Note
RoHs compliant
Cover Material
PA reinforced
Fastening Type
mit Durchgangsbohrung für Schraube M5
Seals Material
NBR
Clamps Material
High-alloyed stainless steels
Sleeve Material
High-alloyed stainless steels
Shock Resistance
Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Diagnosis Via LED
Verbindungsstatus
Max. Power Supply
2 x 4 A (externe Sicherung erforderlich)
Relative Humidity
5 - 95 %
Communication Types
IO-Link
Connection Position
On the side
Electrical Controls
IO-Link
IO-Link, Port Class
B
Protection Category
IP40
Dimensions W x L x H
45,6 mm x 117,4 mm x 53,9 mm
Fuse (Short Circuit)
Internal electronic fuse Per channel
Max. Line Length (m)
20
Oscillation Strength
Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Electrical Connection
Push-in
Max. Setup Height (m)
3.500
LABS (PWIS) Conformity
VDMA24364-B1/B2-L
Pneumatic Connection 1
für Cartridge 15 mm
Pneumatic Connection 5
für Cartridge 15 mm
Valve Island Structure
Valve sizes mixable
Degree Of Contamination
2
Nominal Altitude Of Use
<= 2000 m NHN
Connection Cross-section
0.2 to 1.5
Ambient Temperature (°C)
-5 to 50
Bearing Temperature (°C)
-20 to 70
Connection Plate Material
PA reinforced
IO-Link, Protocol Version
Device V 1.1
Max. Number Of Valve Coils
32
IO-Link, Communication Mode
COM3 (230.4 kBaud)
IO-Link, Minimum Cycle Time
500 µs
Reverse Polarity Protection
yes
Power Consumption At 24 V DC
0,24
Corrosion Resistance Class KBK
2 - moderate corrosion stress
Fastening Type Connection Plate
With throughway bores
IO-Link, Process Data Width OUT
4 Byte
Permissible Voltage Fluctuation Of Load
± 10 %
Nominal Operating Voltage DC Of Load (V)
24
Max. Tightening Torque Wall Assembly (Nm)
6
Intrinsic Power Input Operating Voltage Load
typisch 15 mA
UKCA Marking (See Declaration Of Conformity)
nach UK RoHS Vorschriften
CE Certificate (See Declaration Of Conformity)
nach EU-RoHS-Richtlinie
Permitted Voltage Oscillations Electronics/sensors
± 25 %
Nominal Operating Voltage DC Electronics / Sensor (V)
24
Intrinsic Power Input Operating Voltage Electronics/sensors
typisch 10 mA
Electrical Isolation Of Outputs Between Channel - Internal Communication
yes
Potential Separation Between The Supply Voltages Electronics/sensor Technology And Load/valves
yes
EAN
4052568638504
Manufacturer
Festo