Overlap
positive Überdeckung
Permission
C-tick, c UL us - Recognized (OL)
Reset Mode
Mechanical spring
Control Type
pilot operated
Fastening Type
on connection plate
Valve Function
5/2 monostable
Screws Material
Zinc-plated steel
Exhaust Function
drosselbar, über Drosselplatte, über Einzelanschlussplatte
Housing Material
PA, Aluminium die casting
Operating Medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Shock Resistance
Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Relative Humidity
0 - 90 %
Sensor Connection
M8x1, 3 pin, Plug
Certification Body
UL MH19482
Control Air Supply
external
Construction Set Up
Piston pusher
Protection Category
IP65, NEMA 4
Complies To Standard
ISO 15407-1, VDMA 24563
Material Information
RoHs compliant
Oscillation Strength
Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Electrical Connection
Wiring diagram Form C acc. to EN 175301-803, without protective earthing conductor, acc. to EN 175301-803
Empty Run Sensor (mA)
<= 10 mA
Hand Assist Actuation
Covered
Installation Position
arbitrary
Measurement Principle
Inductive
Pre-control Interface
acc. to ISO 15218
Noise Status Indicator
LED
Pneumatic Connection 1
Connection plate Size 26 mm to ISO 15407-1
Pneumatic Connection 2
Connection plate Size 26 mm to ISO 15407-1
Pneumatic Connection 3
Connection plate Size 26 mm to ISO 15407-1
Pneumatic Connection 4
Connection plate Size 26 mm to ISO 15407-1
Pneumatic Connection 5
Connection plate Size 26 mm to ISO 15407-1
Residual Ripple Sensor
± 10 %
Sensor Voltage Drop (V)
<= 2 V
Operating Pressure (bar)
-0.9 to 16
Signal Condition Display
With Accessories
Switching Position Query
Idle position with sensor
Coil Characteristic Value
24 V DC: 1,8 W
Switching Element Function
NC contact
Sound Pressure Level (dB(A))
85
Corrosion Resistance Class KBK
0 - No corrosion stressing
Permitted Voltage Oscillations
-15 % / +10 %
Max. Output Current Sensor (mA)
200
Short Circuit Resistance Sensor
Cycling
Exhaust Control Connection 82/84
Not recorded, Selectively:, Recorded
Nominal Operating Voltage DC (V)
24
Max. Switching Frequency Sensor (Hz)
5.000
Support Air Control Connection 12/14
Connection plate Size 26 mm to ISO 15407-1
Operating Voltage Range DC Sensor (V)
10 to 30
Valve - Sensor Switching Time On (ms)
60
Valve - Sensor Switching Time Off (ms)
11
Flow Valve Pneumatically Linked (l/min)
1.100
Flow Valve Single Connection Plate (l/min)
1.100
Max. Tightening Torque Valve Fastening (Nm)
1.8 to 2.2
Max. Positive Test Impulse At 0 Signal (µs)
1.000
UKCA Marking (See Declaration Of Conformity)
for all electrical connections
Max. Negative Test Impulse For 1 Signal (µs)
800
CE Certificate (See Declaration Of Conformity)
to EU EMC directive
Information About Operating And Control Medium
Oiled operation possible (required in further operations)
Standard Nominal Flow Rate (Standardised To DIN 1343) (l/min)
1.100