| 19163 | — | Vent valve (Cooling Control Valve) - Short circuit high | Full repair manual for code 19163 |
| 19163 | New Holland Dosing Control Unit Dcu | Cooling control valve short circuit to UBat or open load | Full repair manual for code 19163, New Holland Dosing Control Unit Dcu |
| 19164 | — | Vent valve (Cooling Purge Control Valve) - Open circuit | Full repair manual for code 19164 |
| 19164 | New Holland Dosing Control Unit Dcu | Cooling control valve short circuit to UBat or open load | Full repair manual for code 19164, New Holland Dosing Control Unit Dcu |
| 19172 | — | Short Circuit of the Cooling Valve to 'Mass' | Full repair manual for code 19172 |
| 19172 | — | Vent valve (Cooling Purge Control Valve) - Short circuit low | Full repair manual for code 19172 |
| 19172 | New Holland Dosing Control Unit Dcu | Cooling control valve short circuit to ground | Full repair manual for code 19172, New Holland Dosing Control Unit Dcu |
| 19181 | — | Vent valve (Reverting Purge Control Valve) - Short circuit high | Full repair manual for code 19181 |
| 19181 | — | Short Circuit in Reversing Valve or P20A3 Vapor Vent Valve | Full repair manual for code 19181 |
| 19181 | DCU | Reverting valve (4-2way valve?) electrically | Short circuit to battery | P20A3 Vent valve (Reductant Purge Control Valve) -short circuit high | Full repair manual for code 19181, DCU |
| 19181 | New Holland Dosing Control Unit Dcu | Reverting Valve (4-2 Way Valve) Electrically - Short Circuit to Battery | Full repair manual for code 19181, New Holland Dosing Control Unit Dcu |
| 19182 | — | Reversing valve (4-2-way valve) - electric - short to ground - P20A2 steam vent valve (air dryer control valve) - short to low voltage source | Full repair manual for code 19182 |
| 19182 | — | Vent valve (Reverting Purge Control Valve) - Short circuit low | Full repair manual for code 19182 |
| 19182 | New Holland Dosing Control Unit Dcu | Reverting valve (4-2 way valve) electrically – short circuit to ground – P20A2 vent valve (reductant purge control valve) – short circuit low | Full repair manual for code 19182, New Holland Dosing Control Unit Dcu |
| 19183 | — | Reversing Valve (4-2-way Valve) Electric - Open Load - Steam Release Valve P20A3 - Open Circuit | Full repair manual for code 19183 |
| 19183 | — | Vent valve (Reverting Purge Control Valve) - Open Circuit | Full repair manual for code 19183 |
| 19183 | New Holland Dosing Control Unit Dcu | Reverting valve (4-2 way valve) electrically – open load – P20A0 vent valve (reductant purge control valve) – open circuit | Full repair manual for code 19183, New Holland Dosing Control Unit Dcu |
| 19184 | — | Reverting Valve Electrically - Short Circuit to Ground | Full repair manual for code 19184 |
| 19184 | — | Steam Release Valve (Air Regulator Control Valve) - Short Circuit to Low Voltage Source | Full repair manual for code 19184 |
| 19244 | — | Urea Pump Heater - Short Circuit to +BATT | Full repair manual for code 19244 |
| 19247 | — | Urea Pump Heater - Open Electrical Circuit | Full repair manual for code 19247 |
| 19248 | — | Urea Pump Heater - Short Circuit to Ground | Full repair manual for code 19248 |
| 19262 | — | Heater Tank Valve - Short Circuit to Battery | Full repair manual for code 19262 |
| 19262 | DCU | Tank Heating Valve Short Circuit to Battery | Full repair manual for code 19262, DCU |
| 19262 | New Holland Dosing Control Unit Dcu | Tank Heating Valve – Short Circuit to Battery | Full repair manual for code 19262, New Holland Dosing Control Unit Dcu |
| 19263 | — | Heater Tank Valve - Short to Ground or Low Voltage Source | Full repair manual for code 19263 |
| 19263 | New Holland Dosing Control Unit Dcu | Tank heating valve – short circuit to ground | Full repair manual for code 19263, New Holland Dosing Control Unit Dcu |
| 19264 | — | Heater Tank Valve - Open Load | Full repair manual for code 19264 |
| 19264 | New Holland Dosing Control Unit Dcu | Tank Heating Valve – Open Circuit | Full repair manual for code 19264, New Holland Dosing Control Unit Dcu |
| 19265 | — | Heater Tank Valve - Short to Ground or Low Voltage Source | Full repair manual for code 19265 |
| 19280 | — | Filter Block Heater - Short Circuit on +BAT | Full repair manual for code 19280 |
| 19283 | — | Heater Block - Open Electrical Circuit | Full repair manual for code 19283 |
| 19284 | — | Filter Block Heater - Short Circuit to Ground | Full repair manual for code 19284 |
| 19289 | — | Too low temperature at the catalyst outlet - temperature after catalyst - physical (catalyst heating time error) - range/operation of the catalyst temperature sensor circuit P042B | Full repair manual for code 19289 |
| 19289 | DCU | Catalyst Temperature Sensor Circuit Range/Performance | Full repair manual for code 19289, DCU |
| 19289 | New Holland Dosing Control Unit Dcu | Temperature after catalyst too low – physical | Full repair manual for code 19289, New Holland Dosing Control Unit Dcu |
| 19290 | — | Too low temperature at the catalyst outlet - temperature after catalyst - physical (catalyst heating time error) - range/operation of the catalyst temperature sensor circuit P042B | Full repair manual for code 19290 |
| 19298 | — | Too Low Urea Pressure at System Start | Full repair manual for code 19298 |
| 19298 | New Holland Dosing Control Unit Dcu | Urea pressure too low at system start – reagent pump not delivering | Full repair manual for code 19298, New Holland Dosing Control Unit Dcu |
| 19307 | — | Urea pressure too high - Urea pressure not reliable | Full repair manual for code 19307 |
| 19307 | DCU | Urea Pressure Too High | Full repair manual for code 19307, DCU |
| 19307 | New Holland Dosing Control Unit Dcu | Urea Pressure Too High | Full repair manual for code 19307, New Holland Dosing Control Unit Dcu |
| 19316 | — | Urea temperature in the pump module does not match the specified range | Full repair manual for code 19316 |
| 19316 | — | Urea Temperature in Pump Assembly Out of Range | Full repair manual for code 19316 |
| 19316 | New Holland Dosing Control Unit Dcu | Urea temperature in pump module out of range | Full repair manual for code 19316, New Holland Dosing Control Unit Dcu |
| 19325 | — | Urea Temperature in Tank Out of Allowable Range | Full repair manual for code 19325 |
| 19325 | New Holland Dosing Control Unit Dcu | Urea Temperature in Tank Out of Range | Full repair manual for code 19325, New Holland Dosing Control Unit Dcu |
| 19334 | — | Heating Fault in Intake Manifold | Full repair manual for code 19334 |
| 19334 | DCU | Inlet Line Defreezing Failed | Full repair manual for code 19334, DCU |
| 19334 | New Holland Dosing Control Unit Dcu | System Frozen and Not Free in Time – Inlet Line Defreezing Failed | Full repair manual for code 19334, New Holland Dosing Control Unit Dcu |