(4,046)
Standard tapered posts on European and SAE batteries measure about 19.5 mm at the base for the positive and 17.9 mm for the negative, tapering towards the top. Japanese-pattern small posts, common on compact tractors and utility vehicles with Japanese-format batteries, measure about 14.7 mm positive and 13.1 mm negative. A standard clamp cannot be tightened properly onto a small post, so the clamp must match the post type.
As a guide, 16 to 25 mm² suits small petrol engines and utility vehicles, 35 to 50 mm² suits most tractor diesels on 12 V, and 70 mm² or more is used for large engines or where the battery sits far from the starter. Never go below the original size. A 24 V system carries about half the current for the same power, so its cables are often smaller than those of a comparable 12 V machine.
Disconnect the negative, or earth, terminal first and reconnect it last. With the negative lead off, a spanner that touches the chassis while on the positive terminal cannot cause a short circuit. On machines with electronic control units, switch off the ignition and wait about a minute before disconnecting, so the controllers can shut down.
A typical clamp with an M6 pinch bolt is tightened to about 5 to 7 Nm. The test is that the clamp cannot be twisted on the post by hand. Seat the clamp fully down the taper before tightening and never drive it on with a hammer, which can loosen the post inside the battery. A clamp that bottoms out before it grips has stretched and should be replaced.
Disconnect the leads, negative first, and wash the posts and clamps with a solution of baking soda in warm water to neutralise the acid salts. Brush the contact surfaces to bright metal with a terminal brush, rinse and dry. Refit and tighten the clamps, then coat the outside of the joint with terminal grease or petroleum jelly. Apply the grease after tightening, not between the contact faces.
Measure voltage drop under load rather than resistance. Connect a voltmeter between the battery positive post and the starter terminal and crank the engine: the drop should not exceed about 0.5 V. Between the battery negative post and the engine block it should not exceed about 0.3 V. A higher reading, or a cable that becomes warm or stiff with a swollen section, indicates corrosion inside the insulation and the cable should be replaced.
For 24 V, connect the batteries in series: a link lead joins the positive of one to the negative of the other, and the machine connects to the two remaining posts. Voltage doubles and capacity stays the same. For more capacity at 12 V, connect in parallel, positive to positive and negative to negative. Link leads must have the same cross-section as the main cables, and both batteries should be of the same type, capacity and age.

Hella - 8KW744807801 - Cable Connector - 3-Pin Connector
Hella
€7.46
Showing 1–48 of 4,046 parts