CodeControllerIssue summaryRepair manual
ATC 127ATC (Automatic Temperature Control)High pressure switch (-) input shorted to powerFull repair manual for code ATC 127, ATC (Automatic Temperature Control)
ATC 128ATC (Automatic Temperature Control) moduleHigh pressure switch (-) input shorted to ground.Full repair manual for code ATC 128, ATC (Automatic Temperature Control) module
ATC 129ATC (Automatic Temperature Controller)High pressure cycling error (2 in 1 minute)Full repair manual for code ATC 129, ATC (Automatic Temperature Controller)
ATC 130ATC (Automatic Temperature Control) ControllerLow pressure switch (+) input shorted to powerFull repair manual for code ATC 130, ATC (Automatic Temperature Control) Controller
ATC 131ATC (Automatic Temperature Control) / HVAC ControllerLow pressure switch (+) input shorted to ground.Full repair manual for code ATC 131, ATC (Automatic Temperature Control) / HVAC Controller
ATC 132ATCLow pressure switch (-) input shorted to powerFull repair manual for code ATC 132, ATC
ATC 133ATC (Automatic Temperature Control) controllerLow pressure switch (-) input is shorted to groundFull repair manual for code ATC 133, ATC (Automatic Temperature Control) controller
ATC 134ATC (Automatic Temperature Control) ControllerLow pressure switch open for > 1 minuteFull repair manual for code ATC 134, ATC (Automatic Temperature Control) Controller
DCU 18147DCU (Dosing Control Unit)Dosing Valve (electrical) | open load | P2047 Reductant Injector - circuit openFull repair manual for code DCU 18147, DCU (Dosing Control Unit)
DCU 19001DCUBattery voltage sensing (electrical) signal high / Battery voltage evaluation above upper limitFull repair manual for code DCU 19001, DCU
DCU 19002DCU (Dosing Control Unit)Battery voltage sensing (electrical) | signal low | Battery voltage evaluation below lower limit.Full repair manual for code DCU 19002, DCU (Dosing Control Unit)
DCU 19010DCUTemperature sensor after catalyst (electrical) signal high P042D Catalyst Temperature Sensor Circuit HighFull repair manual for code DCU 19010, DCU
DCU 19011DCUTemperature sensor after catalyst (electrical) | signal low | Catalyst Temperature Sensor Circuit LowFull repair manual for code DCU 19011, DCU
DCU 19019DCU (Dosing Control Unit)Temperature sensor before catalyst (electrical) — signal high / Catalyst Temperature Sensor Circuit HighFull repair manual for code DCU 19019, DCU (Dosing Control Unit)
DCU 19020DCU (Dosing Control Unit)Temperature sensor before catalyst (electrical) | signal lowFull repair manual for code DCU 19020, DCU (Dosing Control Unit)
DCU 19037DCU (Dosing Control Unit)Sensor supply 2 (5V internal; for UREA pressure sensors) — Supply Voltage too highFull repair manual for code DCU 19037, DCU (Dosing Control Unit)
DCU 19038DCUSensor supply 2 (5V internal; for UREA pressure sensors) | Supply voltage too low | Reagent -pressure sensor -short circuit low.Full repair manual for code DCU 19038, DCU
DCU 19046DCUUREA pressure sensor in box (electrical) | supply voltage error | P204A Reagent - pressure sensor - open circuitFull repair manual for code DCU 19046, DCU
DCU 19047DCUUREA pressure sensor in box (electrical) _signal high _P204D Reagent -pressure sensor -short circuit highFull repair manual for code DCU 19047, DCU
DCU 19048DCUUREA pressure sensor in box (electrical) | signal low | P204C Reagent - pressure sensor - short circuit lowFull repair manual for code DCU 19048, DCU
DCU 19055DCU (Dosing Control Unit)UREA Temperature sensor in box (electrical) _high signal _P2045 Reagent -temperature sensor of pump module -short circuit highFull repair manual for code DCU 19055, DCU (Dosing Control Unit)
DCU 19056DCUUREA Temperature sensor in box (electrical) | signal lowFull repair manual for code DCU 19056, DCU
DCU 19064DCU (Dosing Control Unit)Voltage supply internal heaters 1 (UB1) electrical | Open circuit to UB1 | P20C5 Pump module - Internal heating - open circuit.Full repair manual for code DCU 19064, DCU (Dosing Control Unit)
DCU 19065DCUVoltage supply internal heaters 1 (UB1) electrical | Short to bat at UB1 with Key 15 off | Pump module - Internal heating - short circuit highFull repair manual for code DCU 19065, DCU
DCU 19073DCU (Dosing Control Unit)Voltage supply 2 -tube heaters (UB2) electrical | Short to bat at UB2 with Key 15 off | P20C4 Reagent -suction tube heating -short circuit highFull repair manual for code DCU 19073, DCU (Dosing Control Unit)
DCU 19074DCUVoltage supply 2 -tube heaters (UB2) electrical | Open circuit to UB2 | P20C1 Reagent -suction tube heating -open circuitFull repair manual for code DCU 19074, DCU
DCU 19075DCU (Dosing Control Unit)Voltage supply 2 - tube heaters (UB2) electrical | Short circuit to Ground UB2 | P20C3 Reagent - suction tube heating - short circuit lowFull repair manual for code DCU 19075, DCU (Dosing Control Unit)
DCU 19082DCUVoltage supply 3 - Coolant control valve and reverting valve (UB3) electrical | Short to bat at UB3 with Key 15 offFull repair manual for code DCU 19082, DCU
DCU 19083DCUVoltage supply 3 - Coolant control valve and reverting valve (UB3) electrical | Open circuit to UB3 | P20A0 Vent valve (Reductant Purge Control Valve) - open circuitFull repair manual for code DCU 19083, DCU
DCU 19084DCU (Dosing Control Unit)Voltage supply 3 - Coolant control valve and reverting valve (UB3) electrical | Short circuit to Ground UB3 | P20A2 Vent valve (Reductant Purge Control Valve) - short circuit lowFull repair manual for code DCU 19084, DCU (Dosing Control Unit)
DCU 19091DCUMonitoring VDD11 voltage - Dosing valve | supply voltage low | 12 Volt supply for dosing module - below lower limit.Full repair manual for code DCU 19091, DCU
DCU 19092DCUMonitoring VDD11 voltage - Dosing valve supply voltage high P0659 12 Volt supply for dosing module - above upper limitFull repair manual for code DCU 19092, DCU
DCU 19100DCU (Dosing Control Unit)UREA level sensor (electrical) | supply voltage error | Reductant Level Sensor - Circuit Intermittent/ErraticFull repair manual for code DCU 19100, DCU (Dosing Control Unit)
DCU 19101DCUUREA level sensor (electrical) signal high / Reagent - tank level sensor - short circuit highFull repair manual for code DCU 19101, DCU
DCU 19102DCUUREA level sensor (electrical) | signal low | P203C Reagent -tank level sensor -short circuit lowFull repair manual for code DCU 19102, DCU
DCU 19109DCUShort circuit high in UREA (DEF/Reagent) tank temperature sensorFull repair manual for code DCU 19109, DCU
DCU 19110DCU (Dosing Control Unit)UREA Temperature sensor in Tank (electrical) | signal lowFull repair manual for code DCU 19110, DCU (Dosing Control Unit)
DCU 19145DCUDosing Valve (electrical) | short circuit to batt + | Reductant Injector - circuit highFull repair manual for code DCU 19145, DCU
DCU 19146DCUDosing Valve (electrical) | short circuit to ground | P2048 Reductant Injector - circuit lowFull repair manual for code DCU 19146, DCU
DCU 19148DCUDosing Valve (electrical) | Dosing valve permanent ‘ON’ (detection via fast decay) | Reagent-dosing nozzle pressure too highFull repair manual for code DCU 19148, DCU
DCU 19154DCUUREA Pump speed | pump motor unplugged | P208B Reagent-pump not deliveringFull repair manual for code DCU 19154, DCU
DCU 19155DCUUREA Pump speed – pump motor blocked – Reagent-pumpFull repair manual for code DCU 19155, DCU
DCU 19156DCUUREA Pump speed | pump overspeed | Reagent-pump over speedFull repair manual for code DCU 19156, DCU
DCU 19157DCU (Dosing Control Unit)UREA Pump speed | Hall sensors defect | P208B Reagent-pump not deliveringFull repair manual for code DCU 19157, DCU (Dosing Control Unit)
DCU 19163DCUCooling control valve short circuit to UBat or open load | short circuit to battery | P20A3 Vent valve (Reductant Purge Control Valve) - short circuit highFull repair manual for code DCU 19163, DCU
DCU 19164DCUCooling control valve short circuit to UBat or open load | Open load | Vent valve (Reductant Purge Control Valve) - open circuitFull repair manual for code DCU 19164, DCU
DCU 19172DCUCooling control valve short circuit to ground | P20A2 Vent valve (Reductant Purge Control Valve) - short circuit lowFull repair manual for code DCU 19172, DCU
DCU 19181DCUDEF Reverting Valve Short circuit to batteryFull repair manual for code DCU 19181, DCU
DCU 19182DCUReverting valve (4-2way valve?) electrically | Short circuit to ground | P20A2 Vent valve (Reductant Purge Control Valve) - short circuit lowFull repair manual for code DCU 19182, DCU
DCU 19183DCUReverting valve (4-2way valve?) electrically | Open load | P20A0 Vent valve (Reductant Purge Control Valve) - open circuitFull repair manual for code DCU 19183, DCU