All 2,141 codes· 50 per page · page 16 of 43
| Code | Controller | Issue summary | Repair manual |
|---|---|---|---|
| 762Eh | — | Fault in the Powertrain CAN Bus Network | Full repair manual for code 762Eh |
| 762Eh | Claas Tr2 A57 2 Transmission Module | Loss of Theoretical Forward Speed on Powertrain CAN Bus | Full repair manual for code 762Eh, Claas Tr2 A57 2 Transmission Module |
| Id762Eh / 762Eh (415) | TR2 (A57-2) | Loss of the theoretical forward speed on the Powertrain CAN bus information although the gearbox intermediate speed information (on Revershift output) is present on Powertrain CAN bus | Full repair manual for code Id762Eh / 762Eh (415), TR2 (A57-2) |
| 762Fh | — | Fault Code 762Fh - TR2 (A57-2) Module 2 - Pressure < 70 bar during Pump | Full repair manual for code 762Fh |
| 762Fh | — | TR2 (A57-2) Error on high pressure braking. Pressure < 70 bar during initialization. The component identified by this code is module number 2 | Full repair manual for code 762Fh |
| 762Fh | Claas Tr2 A57 2 Transmission Module | Error on high pressure braking | Full repair manual for code 762Fh, Claas Tr2 A57 2 Transmission Module |
| Id762Fh / 762Fh (416) | TR2 (Transmission Control Module) | Error on high pressure braking. | Full repair manual for code Id762Fh / 762Fh (416), TR2 (Transmission Control Module) |
| 763Ah | — | Fault on CAN network (Component 2) | Full repair manual for code 763Ah |
| 763Ah | — | Physical error on the CAN Audio warning (module number 2) | Full repair manual for code 763Ah |
| 763Ah | Claas Tr2 A57 2 Transmission Module | CAN Network Error: Tractor Computers Not Detected or Overloaded | Full repair manual for code 763Ah, Claas Tr2 A57 2 Transmission Module |
| Id763Ah / 763Ah (427) | TR2 (Transmission Control Module 2) | Physical error on the CAN network. At least one of the tractor computers is not detected or CAN network overload. | Full repair manual for code Id763Ah / 763Ah (427), TR2 (Transmission Control Module 2) |
| 763Bh | — | TR2 (A57-2) Module 2 Unable to Read Tractor Specific Parameters in EEPROM Memory | Full repair manual for code 763Bh |
| 763Bh | Claas Tr2 A57 2 Transmission Module | Unable to Read Tractor Specific Parameters in EEPROM Memory | Full repair manual for code 763Bh, Claas Tr2 A57 2 Transmission Module |
| Id763Bh / 763Bh (428) | TR2 (A57-2) Transmission Module / Auto 5 | Unable to read tractor-specific parameters in EEPROM memory. | Full repair manual for code Id763Bh / 763Bh (428), TR2 (A57-2) Transmission Module / Auto 5 |
| 763Ch | — | Loss of Permanent 12 V Supply After Ignition Switch On | Full repair manual for code 763Ch |
| 763Ch | Claas Tr2 A57 2 Transmission Module | Problem Saving Parameters When Placing Units on Standby | Full repair manual for code 763Ch, Claas Tr2 A57 2 Transmission Module |
| Id763Ch / 763Ch (429) | TR2 (A57-2) / Auto 5 | Problem saving parameters when placing units on standby | Full repair manual for code Id763Ch / 763Ch (429), TR2 (A57-2) / Auto 5 |
| 763Dh | — | Check: The battery voltage. The 12V harnesses and connections after contact of the 'Auto 5' modules. | Full repair manual for code 763Dh |
| 763Dh | — | TR2 (A57-2) Unit 12 V supply voltage is less than 7 V after switching on the ignition (component 2) | Full repair manual for code 763Dh |
| 763Dh | Claas Tr2 A57 2 Transmission Module | Low 12 V Supply Voltage After Ignition Activation | Full repair manual for code 763Dh, Claas Tr2 A57 2 Transmission Module |
| Id763Dh / 763Dh (430) | TR2 (A57-2) Transmission Module / Auto 5 module | The unit 12 V supply voltage is less than 7 V after switching on the ignition. | Full repair manual for code Id763Dh / 763Dh (430), TR2 (A57-2) Transmission Module / Auto 5 module |
| 763Eh | — | TR2 (A57-2) 10 V supply to sensors out of tolerance | Full repair manual for code 763Eh |
| Id763Eh / 763Eh (431) | Auto 5 module (TR2 (A57-2) or TR1 (A57-1)) | The 10 V supply to the sensors is not within the ± 5 % tolerance. | Full repair manual for code Id763Eh / 763Eh (431), Auto 5 module (TR2 (A57-2) or TR1 (A57-1)) |
| 763Eh | Claas Tr2 A57 2 Transmission Module | 10 V Supply to Sensors Out of Tolerance | Full repair manual for code 763Eh, Claas Tr2 A57 2 Transmission Module |
| 764Ah | — | Fault Code 764Ah - TR2 (A57-2) Supply Voltage Measured On | Full repair manual for code 764Ah |
| 764Ah | — | TR2 (A57-2) Supply voltage measured on solenoid valve SV2 when the driver is not controlled | Full repair manual for code 764Ah |
| 764Ah | — | Possible 12 V short circuit on the solenoid valve power supply harness | Full repair manual for code 764Ah |
| 764Ah | Claas Tr2 A57 2 Transmission Module | Supply Voltage Measured on Solenoid Valve SV2 When Not Controlled | Full repair manual for code 764Ah, Claas Tr2 A57 2 Transmission Module |
| Id764Ah / 764Ah (443) | TR2 (A57-2) Transmission Control Module | Supply voltage measured on solenoid valve SV2 when the driver is not controlled (setpoint PWM = 0). | Full repair manual for code Id764Ah / 764Ah (443), TR2 (A57-2) Transmission Control Module |
| 764Bh | — | Check for 12 V short circuit on solenoid valve power supply harness | Full repair manual for code 764Bh |
| 764Bh | — | TR2 (A57-2) Actual current measured on the return of solenoid valve SV2 is too high | Full repair manual for code 764Bh |
| 764Bh | Claas Tr2 A57 2 Transmission Module | High Current Measured on Return of Solenoid Valve SV2 | Full repair manual for code 764Bh, Claas Tr2 A57 2 Transmission Module |
| Id764Bh / 764Bh (444) | TR2 (A57-2) Transmission Module / Auto 5 module | SV2 Solenoid Valve Return Circuit Current Too High | Full repair manual for code Id764Bh / 764Bh (444), TR2 (A57-2) Transmission Module / Auto 5 module |
| 764Ch | — | TR2 (A57-2) - Current Consumed by Solenoid Valve SV2 Exceeds 1,4 A | Full repair manual for code 764Ch |
| 764Ch | Claas Tr2 A57 2 Transmission Module | Excessive Current Draw from Solenoid Valve SV2 | Full repair manual for code 764Ch, Claas Tr2 A57 2 Transmission Module |
| Id764Ch / 764Ch (445) | TR2 (A57-2) Transmission Module | The current consumed by solenoid valve SV2 is greater than 1,4 A (maximum allowable). | Full repair manual for code Id764Ch / 764Ch (445), TR2 (A57-2) Transmission Module |
| 764Dh | — | TR2 (A57-2) - Solenoid Valve SV2 Return Current Below Setpoint | Full repair manual for code 764Dh |
| 764Dh | — | Solenoid Valve SV2 (Y335-2) Circuit Issue | Full repair manual for code 764Dh |
| 764Dh | Claas Tr2 A57 2 Transmission Module | Low Current Measured on Solenoid Valve SV2 Return | Full repair manual for code 764Dh, Claas Tr2 A57 2 Transmission Module |
| Id764Dh / 764Dh (446) | TR2 (A57-2) | The actual current measured on the solenoid valve SV2 return is less than the setpoint value. | Full repair manual for code Id764Dh / 764Dh (446), TR2 (A57-2) |
| 764Eh | — | TR2 (A57-2) The current sent to solenoid valve SV2 is insufficient | Full repair manual for code 764Eh |
| 764Eh | Claas Tr2 A57 2 Transmission Module | Insufficient Current to Solenoid Valve SV2 | Full repair manual for code 764Eh, Claas Tr2 A57 2 Transmission Module |
| Id764Eh / 764Eh (447) | TR2 (A57-2) / Auto 5 | Insufficient current sent to solenoid valve SV2 | Full repair manual for code Id764Eh / 764Eh (447), TR2 (A57-2) / Auto 5 |
| 764Fh | — | TR2 (A57-2) Supply voltage measured on solenoid valve SV1 when the driver is not controlled (setpoint PWM = 0) | Full repair manual for code 764Fh |
| 764Fh | — | Fault Code 764Fh - TR2 (A57-2) Supply Voltage Measured On | Full repair manual for code 764Fh |
| 764Fh | — | Possible 12 V short circuit on the solenoid valve power supply harness | Full repair manual for code 764Fh |
| 764Fh | Claas Tr2 A57 2 Transmission Module | Supply Voltage Measured on Solenoid Valve SV1 When Not Controlled | Full repair manual for code 764Fh, Claas Tr2 A57 2 Transmission Module |
| Id764Fh / 764Fh (448) | TR2 (A57-2) Transmission Module / Auto 5 | Supply voltage measured on solenoid valve SV1 when the driver is not controlled (setpoint PWM = 0). | Full repair manual for code Id764Fh / 764Fh (448), TR2 (A57-2) Transmission Module / Auto 5 |
| 765Ah | — | TR2 (A57-2) Stack overload- Random Random operation. – behaviour | Full repair manual for code 765Ah |
| Id765Ah / 765Ah (459) | TR2 (A57-2) transmission module | Stack overload- Random behaviour | Full repair manual for code Id765Ah / 765Ah (459), TR2 (A57-2) transmission module |