CodeControllerIssue summaryRepair manual
UCM 5222UCM (Universal Control Module)Loader Arm Valve (Directional) - Solenoid Raise A Supply Short to GroundFull repair manual for code UCM 5222, UCM (Universal Control Module)
UCM 5231UCM (Universal Control Module)Boom Raise/Lower: Solenoid Lower (B) Supply Open CircuitFull repair manual for code UCM 5231, UCM (Universal Control Module)
UCM 5232UCMBoom Raise/Lower: Solenoid Lower (B) Supply Short to GroundFull repair manual for code UCM 5232, UCM
UCM 5241UCMBoom Raise/Lower: Loader Arm Solenoid(s) Short to PowerFull repair manual for code UCM 5241, UCM
UCM 5242UCMBoom Raise/Lower: Loader Arm Solenoid(s) Short to GroundFull repair manual for code UCM 5242, UCM
UCM 5243UCMBoom Raise/Lower: Solenoids Return Open CircuitFull repair manual for code UCM 5243, UCM
UCM 5251UCM (Universal Control Module)Loader Bucket Valve (Directional) - Solenoid Rollback (A) Supply Open CircuitFull repair manual for code UCM 5251, UCM (Universal Control Module)
UCM 5252UCMLoader Bucket Valve (Directional) - Solenoid Rollback (A) Supply Short to GroundFull repair manual for code UCM 5252, UCM
UCM 5261UCMBucket Rollback / Dump: Solenoid Dump (B) Supply Open CircuitFull repair manual for code UCM 5261, UCM
UCM 5262UCMBucket Rollback / Dump: Solenoid Dump (B) Supply Short to GroundFull repair manual for code UCM 5262, UCM
UCM 5271UCMBucket Rollback / Dump: Loader Bucket Solenoid(s) Short to PowerFull repair manual for code UCM 5271, UCM
UCM 5272UCMBucket Rollback / Dump: Loader Bucket Solenoid(s) Short to GroundFull repair manual for code UCM 5272, UCM
UCM 5273UCMBucket Rollback / Dump: Solenoids Return Open CircuitFull repair manual for code UCM 5273, UCM
UCM 5281UCM (Universal Control Module)Aux Control Function: Solenoid Forward (A) Supply Open CircuitFull repair manual for code UCM 5281, UCM (Universal Control Module)
UCM 5282UCM (Universal Control Module)Aux Control Function: Solenoid Forward (A) Supply Short to GroundFull repair manual for code UCM 5282, UCM (Universal Control Module)
UCM 5291UCM (Universal Control Module)Aux Control Function: Solenoid Reverse (B) Supply Open CircuitFull repair manual for code UCM 5291, UCM (Universal Control Module)
UCM 5292UCMAux Control Function: Solenoid Reverse (B) Supply Short to GroundFull repair manual for code UCM 5292, UCM
UCM 5309UCMBoom Float: Float Button Timed Out (30 sec)Full repair manual for code UCM 5309, UCM
UCM 5313UCMEnhanced High-Flow Auxiliary Option: EHF Enable Switch Short to PowerFull repair manual for code UCM 5313, UCM
UCM 5323UCMEnhanced High-Flow Auxiliary Option: EHF Fwd/Rev Switch Short to PowerFull repair manual for code UCM 5323, UCM
UCM 5371UCMEnhanced High-Flow Auxiliary Option: Forward Solenoid (A) Supply Open CircuitFull repair manual for code UCM 5371, UCM
UCM 5372UCM (Universal Control Module)Enhanced High-Flow Auxiliary Option: Forward Solenoid (A) Supply Short to GroundFull repair manual for code UCM 5372, UCM (Universal Control Module)
UCM 5381UCMEnhanced High-Flow Auxiliary Option: Reverse Solenoid (B) Supply Open CircuitFull repair manual for code UCM 5381, UCM
UCM 5382UCMEnhanced High-Flow Auxiliary Option: Reverse Solenoid (B) Supply Short to GroundFull repair manual for code UCM 5382, UCM
UCM 5391UCMEnhanced High-Flow Auxiliary Option: Solenoids Return Open CircuitFull repair manual for code UCM 5391, UCM
UCM 5392UCMEnhanced High-Flow Auxiliary Option: EHF Pumps Solenoid(s) Short to GroundFull repair manual for code UCM 5392, UCM
UCM 5393UCM (Universal Control Module / Utility Control Module)Enhanced High-Flow Auxiliary Option: EHF Pump Solenoid(s) Short to PowerFull repair manual for code UCM 5393, UCM (Universal Control Module / Utility Control Module)
UCM 5409UCM (Universal Control Module) / Instrument ClusterAux Override Disabled due to Aux Override Button Timed Out (30 sec)Full repair manual for code UCM 5409, UCM (Universal Control Module) / Instrument Cluster
UCM 5501UCMBoom Raise/Lower: Sensor Short to Ground / Open CircuitFull repair manual for code UCM 5501, UCM
UCM 5502UCM (Universal Control Module)Boom Raise/Lower: Sensor Short to PowerFull repair manual for code UCM 5502, UCM (Universal Control Module)
UCM 5504UCMBucket Rollback / Dump: Sensor Short to Ground / Open CircuitFull repair manual for code UCM 5504, UCM
UCM 5505UCMBucket Rollback / Dump: Sensor Short to PowerFull repair manual for code UCM 5505, UCM
UCM 5507UCMAuxiliary Valve Spool Sensor - Sensor Short to Ground / Open CircuitFull repair manual for code UCM 5507, UCM
UCM 5508UCM (Universal Control Module)Auxiliary Valve Spool Sensor - Sensor Short to PowerFull repair manual for code UCM 5508, UCM (Universal Control Module)
UCM 5511UCMBoom Raise/Lower: Implausible State Sensor versus Loader Arm Command, Stuck Spool / Pressure Relief ValveFull repair manual for code UCM 5511, UCM
UCM 5512UCMBucket Rollback / Dump: Implausible State Sensor versus Loader Bucket CommandFull repair manual for code UCM 5512, UCM
UCM 5513UCMAux Control Function: Implausible State Sensor versus Auxiliary CommandFull repair manual for code UCM 5513, UCM
UCM 5601UCMAux Control Function: Loader Auxiliary Solenoid(s) Short to PowerFull repair manual for code UCM 5601, UCM
UCM 5602UCMAux Control Function: Loader Auxiliary Solenoid(s) Short to GroundFull repair manual for code UCM 5602, UCM
UCM 5603UCMAux Control Function: Solenoids Return Open CircuitFull repair manual for code UCM 5603, UCM
UCM 5701UCM (Universal Control Module)Pattern Select (ISO/H): Short to Ground / Open CircuitFull repair manual for code UCM 5701, UCM (Universal Control Module)
UCM 5703UCMPattern Select (ISO/H): Short to PowerFull repair manual for code UCM 5703, UCM
UCM 5811UCMLoader Lock: Implausible StateFull repair manual for code UCM 5811, UCM
UCM 9151UCM (Universal Control Module)CAN Bus Communication: Timed out after 5 seconds ("Bus-Off at CAN-Bus No.1")Full repair manual for code UCM 9151, UCM (Universal Control Module)
UCM 9152UCM (Universal Control Module)CAN Bus Communication: Timed out after 5 seconds ("Bus-Off at CAN-Bus No.1")Full repair manual for code UCM 9152, UCM (Universal Control Module)
UCM 9153UCMCAN Bus Communication: EEC1 Message Timed outFull repair manual for code UCM 9153, UCM
UCM 9154UCM (Universal Control Module / User Control Module)CAN Bus Communication: TSC1 Message Timed outFull repair manual for code UCM 9154, UCM (Universal Control Module / User Control Module)
UCM 9156UCMHydraulics Enable: Button Error from AICFull repair manual for code UCM 9156, UCM
UCM 9158UCMPattern Select (ISO/H): Short to GroundFull repair manual for code UCM 9158, UCM
UCM 9159UCM (Universal Control Module)Pattern Select (ISO/H): Short to GroundFull repair manual for code UCM 9159, UCM (Universal Control Module)