| Code | Controller | Issue summary | Repair manual |
|---|---|---|---|
| F596 | — | Circuit Break of Oil Pressure Sensor | Full repair manual for code F596 |
| F705 | — | Atmospheric Pressure Sensor Fault | Full repair manual for code F705 |
| F-PTO 8001 | Front PTO Controller | Front PTO cab switch is on during tractor power up | Full repair manual for code F-PTO 8001, Front PTO Controller |
| F-PTO 8002 | Tractor Controller Unit (TCU) or Armrest Controller Module (ACM) | Front PTO cab switch open | Full repair manual for code F-PTO 8002, Tractor Controller Unit (TCU) or Armrest Controller Module (ACM) |
| F-PTO 8003 | ATC (Armrest Tractor Controller) or Front PTO control module | Front PTO cab switch short | Full repair manual for code F-PTO 8003, ATC (Armrest Tractor Controller) or Front PTO control module |
| F-PTO 8004 | Front PTO Controller | Front PTO solenoid open circuit or shorted to ground or AD12VU2 voltage is low. | Full repair manual for code F-PTO 8004, Front PTO Controller |
| F-PTO 8005 | ATC (Alta Implement / Armrest Controller) or VCM (Vehicle Control Module) | Front PTO solenoid circuit is shorted to B+ | Full repair manual for code F-PTO 8005, ATC (Alta Implement / Armrest Controller) or VCM (Vehicle Control Module) |
| F-PTO 8006 | Front PTO (F-PTO) Controller | Low side driver is stuck on and no current is sensed. | Full repair manual for code F-PTO 8006, Front PTO (F-PTO) Controller |
| F-PTO 8007 | Front PTO Controller, Armrest Controller (ATC), or ICU (Instrumentation Control Unit) | Front PTO switch is in the on position when the engine is off | Full repair manual for code F-PTO 8007, Front PTO Controller, Armrest Controller (ATC), or ICU (Instrumentation Control Unit) |
| F-PTO 8010 | Front PTO (F-PTO) controller | 12VU2 voltage supply is low. (possible blown fuse*) | Full repair manual for code F-PTO 8010, Front PTO (F-PTO) controller |
| IC 1004 | IC | Hydraulic Oil Filter Restricted | Full repair manual for code IC 1004, IC |
| IC 1009 | IC | Hydraulic Oil Temperature - Over Temperature | Full repair manual for code IC 1009, IC |
| IC 1014 | IC | Cluster System Voltage: Over Voltage > 16.5 V | Full repair manual for code IC 1014, IC |
| IC 1015 | IC | Cluster System Voltage: Under Voltage < 11.5 V | Full repair manual for code IC 1015, IC |
| IC 1025 | IC (Instrument Cluster) | Foot Throttle Sensor: Out of Range - Short to Power | Full repair manual for code IC 1025, IC (Instrument Cluster) |
| IC 1026 | IC (Instrument Cluster) | Hand Throttle Sensor: Out of Range - Short to Power | Full repair manual for code IC 1026, IC (Instrument Cluster) |
| IC 1030 | IC (Instrument Cluster) | Foot Throttle Sensor: Out of Range - Short to Ground / Open Circuit | Full repair manual for code IC 1030, IC (Instrument Cluster) |
| IC 1031 | IC / VCM | Hand Throttle Sensor: Out of Range - Short to Ground / Open Circuit | Full repair manual for code IC 1031, IC / VCM |
| IC 1045 | IC (Instrument Cluster) | Fuel Level Monitoring: Open Circuit | Full repair manual for code IC 1045, IC (Instrument Cluster) |
| IC 1201 | IC / EIC | Hydraulic Oil Filter Restriction: Open Circuit | Full repair manual for code IC 1201, IC / EIC |
| IC 1205 | IC (Instrument Cluster) | Hydraulic Enable (EH Machines) - Hydraulic Enable Output, Short to Power | Full repair manual for code IC 1205, IC (Instrument Cluster) |
| IC 1208 | IC | Seat Switch Validation (EH Machines Only): Plausibility Fault | Full repair manual for code IC 1208, IC |
| IC 3390 | Engine Control Unit (ECU) | Air Filter Restriction Switch Short To Ground | Full repair manual for code IC 3390, Engine Control Unit (ECU) |
| IC 4043 | IC (Instrument Cluster) | Hydraulic Oil Temperature Sender - Short to Ground | Full repair manual for code IC 4043, IC (Instrument Cluster) |
| IC 4044 | Instrument Cluster (IC) | Hydraulic Oil Temperature Sender - Open Circuit | Full repair manual for code IC 4044, Instrument Cluster (IC) |
| IC 4401 | IC (Instrument Cluster) / UCM (Universal Control Module) | Park Brake (Mechanical Machines) - Park Brake Solenoid - Open Circuit | Full repair manual for code IC 4401, IC (Instrument Cluster) / UCM (Universal Control Module) |
| IC 4402 | IC (Instrument Cluster) / UCM (Universal Control Module) | Park Brake (Mechanical Machines) - Park Brake Solenoid - Short to Power | Full repair manual for code IC 4402, IC (Instrument Cluster) / UCM (Universal Control Module) |
| IC 4951 | Instrument Cluster (IC) | Hydraulic Enable (Mechanical Machines) - Hydraulic Interlock Solenoid, Short to Power | Full repair manual for code IC 4951, Instrument Cluster (IC) |
| IC 4952 | IC (Instrument Cluster) | Hydraulic Enable (Mechanical Machines) - Hydraulic Interlock Solenoid Open Circuit | Full repair manual for code IC 4952, IC (Instrument Cluster) |
| IC 5503 | IC (Instrument Cluster) | Hydraulic Enable (Mechanical Machines) - EH Aux Output: Short to Power | Full repair manual for code IC 5503, IC (Instrument Cluster) |
| IC 9004 | IC (Instrument Cluster) | Memory Error - Triple Redundant - Hour Meter - Location 1 Corrupt | Full repair manual for code IC 9004, IC (Instrument Cluster) |
| IC 9005 | IC | Memory Error - Location 2 Corrupt | Full repair manual for code IC 9005, IC |
| IC 9006 | IC (Instrument Cluster) | Memory Error - Triple Redundant - Hour Meter Location 3 Corrupt | Full repair manual for code IC 9006, IC (Instrument Cluster) |
| IC 9401 | IC (Instrument Cluster) | Memory Error - Double Redundant Memory - Corruption Detected And Repaired | Full repair manual for code IC 9401, IC (Instrument Cluster) |
| IC 9403 | Instrument Cluster (IC) | Memory Error - Double Redundant: Unrecoverable Memory Corruption Operable | Full repair manual for code IC 9403, Instrument Cluster (IC) |
| IC 9404 | IC (Instrument Cluster) | Memory Error - Hour Meter Corrupted | Full repair manual for code IC 9404, IC (Instrument Cluster) |
| IC 9405 | IC (Instrument Cluster) | CAN Time Out - Loss of DM1 from UCM | Full repair manual for code IC 9405, IC (Instrument Cluster) |
| IC 9406 | Instrument Cluster (IC) | CAN Time Out - Loss of all communication from UCM | Full repair manual for code IC 9406, Instrument Cluster (IC) |
| IC 9407 | IC (Instrument Cluster) | Memory Error - Unrecoverable Hardware ID | Full repair manual for code IC 9407, IC (Instrument Cluster) |
| IC 9408 | IC (Instrument Cluster) | Memory Error - Unrecoverable Panel ID | Full repair manual for code IC 9408, IC (Instrument Cluster) |
| IC 9410 | IC | CAN Time Out - Loss of EGR Inducement status from EDC | Full repair manual for code IC 9410, IC |
| ICU 14002 | ICU | Trans oil filter switch closed to ground on power up. | Full repair manual for code ICU 14002, ICU |
| ICU 14003 | ICU (Instrumentation Control Unit) | Hyd oil filter switch closed to ground on power up. | Full repair manual for code ICU 14003, ICU (Instrumentation Control Unit) |
| ICU 14005 | ICU | PTO shaft speed data is ERROR or NOT AVAILABLE state from PTO | Full repair manual for code ICU 14005, ICU |
| ICU 14006 | ICU | GOV ENGINE speed data is ERROR or NOT AVAILABLE state from GOV | Full repair manual for code ICU 14006, ICU |
| ICU 14007 | ICU | Engine Over speeding | Full repair manual for code ICU 14007, ICU |
| ICU 14008 | ICU | ENGINE oil pressure data is ERROR or NOT AVAILABLE state from GOV | Full repair manual for code ICU 14008, ICU |
| ICU 14009 | ICU (Instrument Cluster Unit) | Loss of valid ENGINE Hours | Full repair manual for code ICU 14009, ICU (Instrument Cluster Unit) |
| ICU 14010 | ICU | PTO controller off line | Full repair manual for code ICU 14010, ICU |
| ICU 14011 | ICU (Instrument Cluster Unit / Instrumentation Control Unit) | Communications Lost with Vehicle Data Bus 1 and ALL other controllers. | Full repair manual for code ICU 14011, ICU (Instrument Cluster Unit / Instrumentation Control Unit) |